Home
About Us
ECP Machine
Products
Inquiry
Contact Us
External Counterpulsation and method of minimizing end diastolic cardiac external counter pulsation angina therapy-external counter therapy
   For the Doctors
 
External Counterpulsation and method of minimizing end diastolic cardiac external counter pulsation angina therapy-external counter therapy
   For the Patients
 
  External Counterpulsation and method of minimizing end diastolic cardiac external counter pulsation angina therapy-external counter therapy  
  External Counter Pulsation Device Model EECP-HG3
     
 

Specifications of External Counter Pulsation Device Model EECP-HG3

 
 
A) The unit comprises of:-
  1. CPU, Key Board, Mouse and 19” color monitor – all mounted on a steel stand with castors.
  2. Treatment Bed, with hydraulic adjustment upto 30° on the head side, has connectors for fixing the cuffs for lower leg, upper leg and waist of the patient.
  3. Compressor Control Box – containing Compressor Unit, Pressure Tank and Electronic Circuitry.
B) SpO2:-
Oxygen saturation range : 0 to 100%.
Standard Deviation : 60-100%± 2 digits for adults using the Finger Clip Sensor.
C) Triggering Method
External trigger : R-wave of patient ECG.
External trigger ratio : 1:1 or 1:2.
ECG trigger range : 35-125± 1bpm.
D) Filter Technique
Low-pass digital filter dliminates 50/60 Hz and higher frequency interference.
E) Treatment Pressure Range
Adjustable from 100-350 mmHg by PC as needed.
F) Cuffs
1 pair each of small, medium & large cuffs (each set comprising calf cuff & a combined cuff for thigh & waist).
G) Treatment Session Timer
Set treatment time from 15 to 60 minutes maximum. System automatically stops when set time expires.
H) System Protection
Three circuit breakers Mains and Compressor and an emergency stop.
I) Patient Protection
Automatic inflation stops and pressure releases in case of:-
  1. Early extra systole.
  2. High-pressure limit (<350 mmHg).
  3. Heart rate goes outside the range of 35 & 125 bpm.
  4. Emergency hand help stop button is actuated by the patient.
J) Treatment Bed Dimensions
Height 71 cm.
Width 80 cm.
Length 200 cm.
Weight 550 lb (250 KG).
K) Operating Voltage Requirements
230 VAC, 50/60 Hz, 15 A.
L) Operating Environment
Temperature : 50 to 104° F (10 to 40° C).
Relative Humidity : 30 to 75% (no condensation).
Atmospheric Pressure : 700 to 1060 hPa.
Atmosphere free of corrosive gases.
M) Patient File Management
Patient database information : Name Address, Telephone, ID….
N) Accreditations:-
  1. NPIA award (China) for product design.
  2. Product Register No. - 3210135
  3. Therapeutic Mechanism & Clinical Identification No. – (93)YYKJD 05.
  4. ecp is a registered trade mark in India & USA and is a FDA approved treatment modality.
 
© 2012 RMD Mediaids Pvt. Ltd. All Rights Reserved.  